Coil Design for High Frequency Induction Heating
Foreword
In the use of the induction heating process, success depends to a great degree on proper design of the inductors (work coils). The following illustrated text outlines the principles of good coil design which, if carefully adhered to, will eliminate costly failyures and assure best operating efficiency.
Most of the following text is confined to the types of coils which essentially surround the work piece, or a portion of it, during the heating operation. The increasing need for higher production through mechanization or automation often makes it necessary to design coils therough which the work can be conveyed, or coils of U-shape which only partially surround the work pieces and permit unimpeded passage on an external conveyor. Such coils are generally referred to as “conveyor type.” Their design is discussed in the last section of this text.
Since the inductor coil itself is only a part of the generator output system, it is of equal importance that some of the same principles of design be applied to the leads which connect the coil to the output terminals of the generator or remote heating station, as the case may be. A short discussion of this subject also will be found at the end of this text.
Inductors for induction heating, usually referred to as heating coils, can be made in a large variety of types and styles- depending on the shape of the metal surface to be heated- but their design must follow certain principles if maximum efficiency of the high frequency generator is to be obtained. Generally speaking, localized induction heating is limited only by the ability to construct a coil to suit the surface to be treated and the matching capacity and power output of the generator. In other words, the generator should have sufficient power to heat the surface quickly.
Many applications of induction heating using frequencies from 10 to 400 kHz, are for brazing and hardening operations, for which the coils are somewhat similar in design. In hardening, some means of quenching is required, either by a spray quench ring or by dropping the part after it is heated into a quench tank containing the proper bath; for brazing this is not needed.
The induction coil quickly raises the temperature of a workpiece by means of a high frequency current which passed through the coil, such as shown in Fig. 1. The coil becomes the primary of a transformer, so to speak, and the work becomes the secondary. The material to be heated is in no way a part of the closed electrical circuit so the generation of heat is solely by induction.

Induction coils may be either of multi-turn design, or in the form of a single-turn coil as shown in Fig. 2, the latter often being termed a “solid” inductor. In either case, copper is invariably used in their construction, and cooling by means of water is absolutely essential. The path of magnetic flux in the cylindrical coils is shown in Fig. 3. The direction of the magnetic lines is determined by the direction of the current as it flows through the inductor coil.


Heating of metal parts is the result of internal energy losses within the material being treated, which cause the temperature to rise. In ferrous materials as shown in Fig. 4, these losses are through hysteresis and eddy-currents up to the curie point, where magnetic properties cease to exist, and from there on (about 1400 degrees F) heating is attained only through eddy-current losses. In non-magnetic materials the only losses present are eddy-current losses; therefore, the induction of heat into such parts requires more power or time.

Since magnetic fields occur in the area surrounding the coil, and are strongest next to it, there is an advantage in placing the workpiece close to the coil so that the maximum heat energy may be transferred to it. The strength of the field varies inversely with the square of the distance between the work and the coil, which means that this consideration will have a direct relation to the amount of heat generated in a workpiece in a given length of time.
In Fig. 5, may be seen two single-turn coils, one having a close coupling and the other a loose coupling. Usually, a close coupling from 3/32” to 1/8” will be found satisfactory for outer-surface heating where a thin skin heat is desired, whereas with a wider coupling the generation of heat will require more time and the penetration will be deeper.

With multi-turn coils closely coupled to a workpiece, there is a tendency for the eddy-currents to provide a heat pattern corresponding to the helix of the coil. The wider of the pitch of the coil, the more pronounced this pattern will be- therefore, a closely wound coil or rotation of the workpiece may be required. When the coil is more loosely coupled, that is at a greater distance from the surface to be heated, the stream of eddy currents spreads over a wider area and rotation of the work may not be necessary.
In making multi-turn coils of copper tubing, a wide variety of shapes is permissable, as shown in Fig. 6. The most common is a cylindrical coil, as at A, which is suited to surface heating of shafts and round parts. The rectangular or square coil at B, as well as the irregular shaped coil at C, are also used for heating the outer surfaces of bars or shafts and easily can be formed and wound over a wooden block. The pancake coil at D is used for heating flat surfaces, such as clutch jaws, or ends of shafts, while the spiral-helical coil E is used for heating conical surfaces, such as bevel gears. The coil at F is of the internal type and is used for heating inner surfaces of holes.

Other suggested types of induction coils made of copper tubing, arranged for heating irregular surfaces may be seen in Fig. 7. The coil at A heats the surface around the slot, while the coil at B heats the end section of a formed steel bar. Coil C, somewhat similar in shape, heats one edge and the fillet of a plate, one view illustrates the position during heating. With irregular surfaces, such as these, requiring coils of intricate shape, it often becomes necessary to experiment somewhat until the correct heat pattern is obtained. Sometimes, only the spreading of the coil, one way or another, might offer the results desired, whereas in other cases a completely new shape may have to be wound.

Because of the path of magnetic flux around a cylindrical coil as at A, Fig. 8, the greatest field strength will be obtained within the coil itself, rather than on the outside. For this reason, outside surface heating of parts, such as shafts, can be performed exceedingly fast. With a flat- or pancake-type coil, as at B, heating will be somewhat slower, per square inch of area, or roughly 75 percent that of the example at A. With internal-type coils, as shown at C, heat transfer is still slower- because less magnetic flux is concentrated on the work surface- and heating may only be 50 to 60 percent as rapid as outside heating. These estimates are based on the use of a high frequency generator of a given output power. For non-ferrous materials, heating times will be somewhat greater than for ferrous materials, usually on the order of 1.5 or 2 to 1.

Since the density of the magnetic flux is less on the outside of a coil than on the inside, and because the greatest strength lies next to the coil, it is advisable to make internal coils in such a way that the overall distance from the surface of the hole being treated and the inner surface of the coil is held to an absolute minimum. In A, Fig. 9, is shown a multi-turn coil of usual design which, when applied within a hole, would result in the dissipation of heat energy due to the excessive overall depth between the work surface and inner diameter of the coil.
At B, the condition is greatly improved by reducing the coupling between the work and coil and flattening the tubing so that the overall depth is held to a minimum, assuring maximum heat energy since the magnetic flux is more constricted to the heated area. The coupling for internal heating coils should be made no more than 1/16”, and less if possible. Magnetic flux concentrator material is sometimes used inside the coil to push the field towards the outside of the coil.

Internal coils for hole heating usually are limited in size due to their mechanical construction, and usually a 5/8” hole is the smallest that can be heated with a multi-turn coil, as shown at A, Fig. 10. Another form of internal coil is the double-turn coil; B; in which the coil is flattened to provide maximum heat transfer. In making coils of this type, care should be taken to avoid closing-in of the tubing so that the water passage will not be restricted. Also, because the heat pattern within the hole is likely to resemble four longitudinal bands, the workpiece should be rotated during heating.

The “hairpin” coil at C also is practical for small hole heating, but the part must be rotated during heating to assure uniformity of heat dissipation. Usually, internal coils of the types shown are limited to surfaces in which the height of the heated surface is not more than twice the diameter. Where the length is on excess of this ratio, progressive heating should be provided if possible, in which case, the heat concentrated to a small area of the hole while the work, itself, feeds at a uniform rate, depending upon available output capacity of the generator and the size of the hole.

In Fig. 12 and 13, suggestions are shown for the construction of copper tube coils. Such coils usually are made of tubing, Fig. 11, ranging from 1/8” to 3/8” in diameter. The 1/8” size should be used very sparingly, however, because of its small area and inasmuch as the flow of cooling water is likely to be too small to prevent over-heating. For short heating cycles, where a slight heating of the coil may have no effect, this size could be considered. However, the larger sizes are preferred.
Round copper tubing can be used for many types of coils, as shown in A, Fig. 12, although it usually is preferable to flatten the tubing as illustrated at B. Another very practical form is the square or rectangular shape shown at C. It also is possible to use a larger diameter tubing, such as 5/8” or 3/4”. as shown at D, and to produce a flat coil similar to a solid inductor previously mentioned.

In making helical copper-tube coils where a restricted heat zone is desired, the coils should be made with an offset, as shown at A, Fig. 13, so that uniform heating can be provided. At B, is shown a means of providing a brace for large diameter coils, which might have a tendency to sag or go out of shape. These braces provide unusual stiffness and, as shown, are attached by means of brazing small rivets to the coil section and heading the rivets over on the outside of the braces. These braces can be made of thin asbestos board, or a laminated plastic material.

SOLID-TYPE induction coils are made of rolled copper plate, as illustrated in Fig. 14 and Fig. 15, and can be arranged for single or multiple operation. The coil shown in Fig. 14, which is typical for brazing parts simultaneously, is made of a thick copper plate, bored to suit the diameter of the part so that sufficient coupling can be provided. Two connecting blocks are brazed to this plate, then the plate is sawed out, as shown, so the high-frequency current will follow the path of the arrows- coming in at one block, and going out the other.

At A, Fig. 15, is shown a single-station coil of similar design, showing a suitable method of providing the necessary cooling. A groove is milled around the coil, and a copper tube is brazed in place. At B is shown another solid-type inductor, in which the cooling chamber is provided by milling a slot around the outside edge and brazing a sheet-metal cover over it.
The water outlet to the two connectors is made by drilling a hole through them and connecting a small tube as shown. Another type of solid inductor is illustrated at C, which includes a band of copper to which a section of flattened tubing is brazed to the outer edge.

A typical two-station brazing coil of the solid-type is shown in Fig. 16. This coil is used for brazing the two sections shown at the right, a ring of silver brazing material being applied. As can be seen, this coil is provided with a cooling tube around its outer edge, whereas the coil is saw-cut, as previously described, to provide the uniform flow of current around both parts.

Still another form of solid-type inductor coil is illustrated in Fig. 17. In this case, six parts are brazed simultaneously. The part seen in front of the coil comprises a dome and a spacer which are assembled together and then centered on the studs shown projecting from the fixture base.

There is a limit to the length of surface which can be hardened at one time, and while no fixed rule applies, a helical coil should not be more than three to four times its diameter, whereas a single-turn coil will be found more effective when the length does not exceed more than half the diameter. The example shown at A, Fig. 18 is obviously too long, since too great a surface is being heated at one time with the result that deflection may occur, as well as the possibility of an uneven distribution of heat. For a surface of this type, assuming that hardening is required, it would be much better to use a shorter coil, and then progressively feed the part through it, such as shown at B.

Usually, when heating a tapered surface, the coil is made to conform with the taper, although exceptions may be considered as in Fig. 19, which shows a fixed diameter coil arranged so the pitch of the winding is wider at the large end than at the small end. With this design, a greater concentration of heat will be provided at the small end, in view of the variation in pitch.

It is well to remember that with a fine pitch coil, the penetration of heat will be deeper than with one having a coarser pitch. Usually, the spacing between coils should not exceed half the diameter of the coil and, of course, less than that is better.
In heating conical parts, such as bevel gears, a coil with a consistent spacing or coupling will result with a more intense heat at the small end, as shown at A, Fig. 20. To compensate for this condition, the coil should be made with a wider angle at the small end, as shown at B, so heating will be uniformly distributed.
The same procedure is true when using a solid inductor coil, shown at C. In heating flat surfaces, such as illustrated at D, a coil made parallel to the face will have a tendency to create the greatest heat toward the center. Coils for such surfaces, therefore, should be made slightly conical or angular, as shown at E.

Multi-turn copper tube coils can also be made of a single winding, whereas another practical design is that shown at Fig. 21, in which the coils are made separately and then joined together by jumpers or connectors. The hose shown at the top is used for providing a continuous flow of water through all four coils.

From the foregoing, it will be seen that induction coils forinduction heating can be constructed in a variety of ways and that a broad field of localized heating of metal parts is made possible by their use. Every application requires some analysis, some more than others, yet the average coil can be made without much difficulty, even with limited experience. With proper facilities and materials on hand, induction coils for new applications can be completed in a relatively short time so that economies of induction heating – low operating cost, a high rate of output and accurate control of heating – can be more broadly applied.
CONVEYOR TYPE WORK COILS
The preceding text is concerned with the heating of metal parts held in a definite relationship to the heating coil. While this is desirable when large amounts of power are to be concentrated in small surface areas, there are many instances when the metal part can be heated by continuously or intermittently passing it through, under or over the coil, when heating for hardening, brazing, soldering, forging and annealing.
If it were desired to pass the parts through the coil, the latter would be designed with bridges on each end to maintain a continuous loop as shown in Fig. 22. It need not be limited to one or two turns as required to cover the area to be heated or to maintain the proper matching of the generator output circuit.
Fig. 23 illustrates two single turn coils that are series connected to allow the intermittent or continuous passage of parts that require heating on both ends.
When parts are to be passed over or under the work coil, the bridges are eliminated and a “pancake” coil of one or more turns is utilized, as represented in Fig. 24.
The efficiency of coils that fully surround the part being heated is far greater than would be experienced with the partially or non-surrounding conveyor type. Pancake coils have the lowest efficiency of any type, since only a small portion of the available energy can be induced into the parts being passed over or under the coil. This is another example where flux concentrator material can be used to increase coupling to the work.



COIL LEAD CONSTRUCTION
The efficiency of all types of coils can be reduced to the point where the induction equipment can appear to be functioning improperly if the leads from the generator or remote heating station to the coil are not suitably designed. If the spacing between the leads is excessive or they are made from copper conductors that are not sufficiently wide, the power loss will be great. Where two or more coils are being operated simultaneously from a single output as in Figs. 25, 26 and 27, it is desirable to have the interconnecting bus spacing maintained uniformly and as close as possible without having voltage breakdown. Generally a spacing of 1/8” or less can be maintained satisfactorily.
The leads connecting the coil or coils to the RF output must also be maintained with this same spacing and, to minimize the loss of power, 2” to 4” wide flat copper 1/16” to ¼” thick is soldered or silver brazed to the coil leads as shown in Figs. 22, 23, 24 and 25. One or more sheets of a dielectric material such as Teflon are placed between the flat copper plates to maintain the desirable spacing of 1/8” or less.
To secure the leads and maintain the spacing, plastic or ceramic bushings or nylon hardware are employed on one side of the lead and an oversize hole is drilled in the lead to allow a brass screw or bolt to pass through without coming in contact with the one lead. The nut and washer locking the assembly together can be in contact with the second lead. The screw must be of brass or non-magnetic stainless steel and must be completely insulated from one of the two leads to prevent a short circuit or voltage breakdown. This construction is recommended for all coils operating from an RF generator to gain optimum efficiency.